Mars 70801 Instruções de Operação Página 6

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 5
6
Operating The New Thermostat
1) Set the System switch to either the HEAT or COOL position and the Fan switch to either the AUTO or ON
position. NOTE: In AUTO, the system blower will run only when the A/C or heat is running. In ON, the
system blower will operate continuously.
2) Use the red and blue arrow keys to select the desired temperature set point.
3) The LCD (liquid crystal display) displays the room temperature on
the left and the set point temperature on the right. Note: The set
point temperature may sometimes differ slightly from the room
temperature due to a rapidly changing room temperature or a dif-
ferential setting of 1 or 2.
Understanding Additional Features
High Temperature Protection: While in the HEAT position, if the room temperature reaches 93 F (34 C),
the thermostat will automatically shut off. In the unlikely event the room temperature reaches 99 F (37 c),
a mechanical bimetal switch will shut off the thermostat.
Low Temperature Protection: While in the HEAT position, if the room temperature drops below 40 F (4
C), the thermostat will automatically initiate a call for heat.
Compressor Protection: To protect the system compressor(s) from damage, the thermostat features a 5
minute delay. After the cooling system (or heat pump turns off), the thermostat will not allow it to re-start
until the 5 minute delay expires. A blinking snowflake indicates this feature has been activated. Once the
5 minute delay expires, the snowflake will illuminate continuously and the system will be able to re-start
when called upon.
NOTE: For the purpose of unit installation, this delay can be overridden by
depressing the RESET button. This will erase any programmed settings.
System Reset: The thermostat can be reset to factory software settings. All user entered settings will be
lost. The reset will also override the 5 minute compressor protection feature. To reset the thermostat, gen-
tly press the reset button on the front panel using a paper clip or similar small pointed object.
Image shows room temperature
of 78 and A/C set point of 68.
70801-IM 12/14/06 3:06 PM Page 6
Vista de página 5
1 2 3 4 5 6 7 8 9 10 11 12

Comentários a estes Manuais

Sem comentários